Formulario de contacto

Extracción de ácidos nucleicos mediante el método de perlas magnéticas.: preciso y eficiente “receptor de genes”

En el campo de la biología molecular y el diagnóstico médico., La extracción de ácidos nucleicos es el primer paso para desbloquear el código genético.. From the detection of novel coronavirus nucleic acid to cancer gene analysis, the purity and yield of nucleic acid directly affect the accuracy of the results. En los últimos años, the magnetic bead nucleic acid extraction technology, with its efficient, flexible and automatic characteristics, has gradually replaced the traditional phenol chlorine method and centrifugal column method, and become thestar tool” del laboratorio.

1. Principles and procedure of nucleic acid extraction by magnetic bead method

The core of the magnetic bead method is the use of surface-modified magnetic nanoparticles (acerca de 50-500 nm in diameter) to bind to nucleic acids by electrostatic adsorption, interacción hidrofóbica, or specific ligands (such as silicon hydroxyl and carboxyl groups). Its operation process includes the following steps:

Sample lysis: The lysate destroys the cell membrane / viral capsid and releases the nucleic acid;

Magnetic bead binding: magnetic beads specifically bind with nucleic acids to form anucleic acid-magnetic bead complex”;

Separación magnética: an external magnetic field to adsorb magnetic beads, discard the impurity liquid;

Lavado: buffer to remove proteins, polysaccharides and other contaminants;

elución: The low-salt solution separates the nucleic acid from the magnetic beads to obtain a high-purity nucleic acid.

This process does not require centrifugal column or organic solvent, only magnetic frame, greatly simplifying the operation steps.

2. Comparison of the magnetic bead method with the conventional method

A. Traditional phenol-chlorine method: tedious and dangerous

Principio: Nucleic acid is extracted by organic solvents such as phenol and chloroform, and separated by centrifugation;

Disadvantages: complex steps (need multiple centrifugation), the use of toxic reagents (harm to health), low recovery rate (easy to cause nucleic acid fracture or loss), and difficult to automate.

B. Método de columna centrífuga: a compromise choice

Principio: Nucleic acid combined with silica gel membrane centrifuge column, purified by centrifugal force;

Ventajas: alta pureza, suitable for conventional samples;

Disadvantages: relying on centrifuge, cumbersome steps (multiple liquid transfer), the effect is unstable, and the cost of centrifugal column consumables is high.

do. Método de cuentas magnéticas: a comprehensively upgraded technology

Eficiencia: high degree of automation, can process hundreds of samples at the same time, time-consuming shortened by more than 30%;

Sensibilidad: the recovery of trace samples (such as plasma free DNA) es 20% -30% higher than the centrifugal column method;

Adaptability: can handle complex samples (such as feces, suelo, FFPE tissue), with strong anti-interference ability;

Environmental protection and safety: reduce the use of organic solvents and reduce the pollution risk.

3. Core advantages of the magnetic bead method

High throughput and automation: adaptive automatic nucleic acid extraction instrument, suitable for large-scale screening (such as COVID-19 detection);

High purity and high yield: the magnetic bead surface functional group selective adsorption of nucleic acid, the impurity residue rate is lower than the traditional method;

Flexible customization: magnetic beads can modify different functional groups, adapt to DNA, RNA or specific fragment extraction requirements;

Quick response: solo 30 minutes from sample to result, helping with emergency scenarios such as the epidemic.

4. Application scenarios and future prospects

Diagnóstico médico: the core steps of COVID-19, HPV and tumor marker detection;

Scientific research fields: secuenciación unicelular, environmental microbiome analysis;

Seguridad alimentaria: to detect pathogenic bacteria or genetically modified ingredients in food.

En el futuro, the magnetic bead method will further develop towards miniaturization (such as microfluidic chip integration) and intelligence (AI control process), and promote the popularization of precision medicine and point-in-time detection(POCT).

5. Notes and common misunderstandings

Myth 1: The more magnetic beads, the better? Excessive magnetic beads will adsorb impurities, but reduce the purity;

Myth 2: The more washing, the better? Excessive washing may lead to nucleic acid loss;

Key point: the appropriate magnetic bead and reagent system should be selected according to the sample type to avoid blind replacement.

Proveedor

Shanghai Lingjun Biotecnología Co., Limitado.se estableció en 2016 que es un fabricante profesional de materiales biomagnéticos y reactivos de extracción de ácidos nucleicos..

Tenemos una rica experiencia en extracción y purificación de ácidos nucleicos., purificación de proteínas, separación celular, quimioluminiscencia, y otros campos técnicos.

Nuestros productos son ampliamente utilizados en muchos campos., como pruebas médicas, pruebas genéticas, investigación universitaria, mejoramiento genético, etcétera. No solo proporcionamos productos sino que también podemos realizar OEM, ODM, y otras necesidades. Si tienes una necesidad relacionada, no dude en contactarnos .

Actualizaciones del boletín

Ingrese su dirección de correo electrónico a continuación y suscríbase a nuestro boletín